*Click Here to refer ARMS® POS support weight scale device model.


Download Software and Required and Install Software

  1. Click Here to download weighing scale machine (Digi SM-100 / Digi SM-320P) 's driver and Install.
  2. Click Here to download backup jdigistore_20191008_161026_2.7.3.5_2.106.zip.
  3. Rename backup filename from "jdigistore_20191008_161026_2.7.3.5_2.106.zip" to " jdigistore_20191008_161026_2.7.3.5_2.106.backup".

Setup IP Address in Digi SM-100 / Digi SM-320


Re-zero Button Mode Button  Enter Button

  1. Connect the weighing scale machine to the Ethernet.
  2. Switch on the weighing scale machine.
  3. Press Mode button until Z Mode.
  4. Hold the Re-zero button and press 0416.
  5. Enter first 3 IP Address 010002001 (Eg: 10.2.1.99) then press PLU button.
  6. Hold the Re-zero button and press 141.
  7. Press 135x.
  8. Enter last IP Address 099 (Eg: 10.2.1.99)  and press Enter button, then press PLU button.
  9. Restart the weighing scale machine.
  10. Press Mode button until Z Mode.
  11. Hold the Re-zero button and press 141.
  12. Press 49x.
  13. Enter 2 then press Enter button.
  14. Enter 1 then press Enter button.
  15. Press PLU button.
  16. Restart the weighing scale machine.

Setup Digi SM-100 / Digi SM-320



Step 1: Connect the weighing scale machine to the Ethernet and switch on the weighing scale machine.

Step 2: Login to the @Label Lite system (localhost:8080/jdigistore) 

Login ID: admin

Password: teraoka


Step 3: Copy the backup file in Step 2 and paste it to C:/jdigistore/dbbackup

Step 4: Go to the @Label Lite system, click on Tools from the Menu, then click on Database


Step 5: Select the backup file, click on Restore button.

Step 6: Once confirm, click on Yes button.


Step 7: Close the browser and reopen it after 5 minutes.

Step 8: Before reopen the browser, go to Windows Services.

Step 9: Stop 3 services (Digistore Application Server, JStoreBus for Digistore and JStoreUpdate for DigiStore).

Step 10: Start again this 3 services (Digistore Application Server, JStoreBus for Digistore and JStoreUpdate for DigiStore).



Step 11: Login to the @Label Lite system, click on Tools from the Menu, then click on Import Templates.

Step 12: Double click on the "Barcode Format Flag1 and Flag2", change the Start Position from 0 to 1, then click on Submit button.

Note: Barcode Format Flag 1 and Flag 2 value, please refer ARMS GO/Premium POS Setting Control.



Step 13: Click on Templates Setting button, change File Name End from txt to csv., then click on Submit button.


Step 14: Click on Scale from the Menu, then click Scale List.

Step 15: Double click on the row with Scale Code 203.


Step 16: Key in Scale IP (Eg: 10.2.1.99) and Scale Type (SM100), then click on Submit button.


Step 17: Click on Scale from the Menu, then click Scale Task.


Step 18: Check the weighing scale machine's network status. Make sure the network status is in On-line state. You can refresh the Web page in order to see the changes.


Step 19: Click Here to sync items to Weighing Scale Machine (Digi SM-100/ Digi SM-320)

Continue to Part 2: How to install wget & run in Schedule